The same packet SRAM byte has several representations, one per hardware user. They are not interchangeable, and mixing them corrupts memory silently instead of faulting.
Address classes
| Class | Form | Used for |
|---|---|---|
| CPU address, runtime pool | 0x0900_7000–0x0901_662f |
CPU loads and stores, software ownership records |
| CPU address, RX FIFO | 0x0940_0000–0x0940_7fff |
CPU access to FIFO slots |
| MAC packet offset | cpu & 0x007f_ffff |
MAC registers and command-word operands |
| DMA bus address | cpu & 0xf6ff_ffff |
HIF descriptors, AES source and destination, packet DMA |
| A-MPDU transfer word | 0x6500_0000 | (cpu & 0x001f_fffc) |
MAC command streams only |
| RX FIFO offset | below 0x7000 |
Producer and consumer registers |
For example, the HIF input buffers at CPU address 0x0900_800c appear as MAC offset 0x0000_800c and bus address 0x0000_800c, and an aggregate member there is transferred with the word 0x6500_800c. A FIFO slot at offset 0x0120 is read by the CPU at 0x0940_0120.
Conversion rules
- Encode only from a CPU address. Every hardware form is derived from a CPU address that belongs to a known object.
- Never decode. A hardware word is not a CPU pointer, and OR-ing a base back into it does not make one. The firmware recovers the CPU address from its own records instead: the HIF queue entry, the TX pipe registry or the A-MPDU software record.
- Check the whole range. An address is valid only if the complete access, not just its first byte, lies in one object.
- Wrap FIFO offsets, not slots; see Receive DMA.